{"id":3434,"date":"2026-07-09T09:46:35","date_gmt":"2026-07-09T13:46:35","guid":{"rendered":"https:\/\/ressources.novatech.ca\/?post_type=blog&#038;p=3434"},"modified":"2026-07-09T14:37:31","modified_gmt":"2026-07-09T18:37:31","slug":"analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride","status":"publish","type":"blog","link":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/","title":{"rendered":"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"3434\" class=\"elementor elementor-3434 elementor-3433\" data-elementor-post-type=\"blog\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fbb85f6 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"fbb85f6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4aafe1c\" data-id=\"4aafe1c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-730f876 elementor-widget elementor-widget-image\" data-id=\"730f876\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-150x150.png\" class=\"attachment-thumbnail size-thumbnail wp-image-3140\" alt=\"Stuart Simmonds - Novatech\" srcset=\"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-150x150.png 150w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-300x300.png 300w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-768x768.png 768w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447.png 1011w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ad4897 elementor-widget elementor-widget-text-editor\" data-id=\"3ad4897\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R\u00e9dig\u00e9 par <strong><a href=\"https:\/\/www.linkedin.com\/in\/stuart-simmonds-1936b0117\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Stuart Simmonds<\/span><\/a><a href=\"https:\/\/www.linkedin.com\/in\/stuart-simmonds-1936b0117\/\" target=\"_blank\" rel=\"noopener\"> &#8211; <\/a><\/strong><span style=\"font-size: 10pt;\"><em>VP <span class=\"_fadeIn_pfttw_8\">D\u00e9veloppement\u00a0<\/span><span class=\"_fadeIn_pfttw_8\">des\u00a0<\/span><span class=\"_fadeIn_pfttw_8\">affaires &amp;\u00a0<\/span><span class=\"_fadeIn_pfttw_8\">Marketing<\/span><\/em><\/span><\/p><p>7 Juillet, 2026<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b0d9f62 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"b0d9f62\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-39999a8\" data-id=\"39999a8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cdb32df red-dot elementor-widget elementor-widget-heading\" data-id=\"cdb32df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/novatech.ca\/preventative-maintenance-and-repair\/\" target=\"_blank\">AMETEK Western Research est \u00e0 l\u2019avant-garde de l\u2019analyse pour la r\u00e9cup\u00e9ration du soufre depuis plus de 50 ans.\n<br>\n\n<br>Au fil des ann\u00e9es, l\u2019entreprise a d\u00e9velopp\u00e9 diff\u00e9rentes architectures d\u2019analyseurs de gaz r\u00e9siduaires afin de r\u00e9pondre \u00e0 diverses exigences environnementales et applicatives dans les unit\u00e9s de r\u00e9cup\u00e9ration du soufre. Traditionnellement, deux grandes options \u00e9taient utilis\u00e9es : une architecture d\u2019analyse extractive, qui permet d\u2019installer l\u2019analyseur \u00e0 distance dans un b\u00e2timent ou un abri, et une architecture mont\u00e9e directement sur la conduite, qui r\u00e9duit le besoin d\u2019un syst\u00e8me traditionnel de conditionnement d\u2019\u00e9chantillon extractif en rapprochant la mesure du proc\u00e9d\u00e9.\n<br>\n\n<br>AMETEK propose maintenant une troisi\u00e8me option : l\u2019AMETEK Western Research 888L, un analyseur hybride de gaz r\u00e9siduaires con\u00e7u pour faire le pont entre ces deux approches.<br>\n\n<br>Le 888L combine l\u2019\u00e9chantillonnage directement sur la conduite avec la possibilit\u00e9 d\u2019installer l\u2019interface de l\u2019analyseur \u00e0 distance, par exemple dans un b\u00e2timent d\u2019analyseurs ou un abri. Cela permet aux utilisateurs de tirer parti de l\u2019architecture AMETEK 888 tout en r\u00e9pondant \u00e0 certaines contraintes environnementales ou d\u2019accessibilit\u00e9 qui les auraient auparavant orient\u00e9s vers une installation extractive de type 900ADA.<br>\n\n<br>Dans les applications de r\u00e9cup\u00e9ration du soufre, le choix d\u2019un analyseur est rarement une simple d\u00e9cision de remplacement d\u2019un produit par un autre. Les longues lignes d\u2019\u00e9chantillon chauff\u00e9es, les points froids, l\u2019emplacement d\u2019installation, les diagnostics et l\u2019acc\u00e8s pour la maintenance influencent tous la fiabilit\u00e9 de la mesure \u00e0 long terme.<br>\n\n<br>La bonne question n\u2019est pas seulement : quel analyseur devrions-nous utiliser?<br>\nC\u2019est plut\u00f4t : quelle architecture d\u2019analyseur convient le mieux au fonctionnement r\u00e9el de cette unit\u00e9?\n<\/a><\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-837aa6e liste-chiffre-big elementor-widget elementor-widget-text-editor\" data-id=\"837aa6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"padding-left: 40px;\"><span style=\"color: #bf2f38;\"><strong>Ce que vous apprendrez dans cet article :<\/strong><\/span><\/h3><div><span style=\"color: #bf2f38;\"><strong>\u00a0<\/strong><\/span><span style=\"color: #bf2f38;\"><strong>\u00a0<\/strong><\/span><\/div><ul><li><em>Comment les architectures d\u2019analyse extractive, mont\u00e9e directement sur la conduite et hybride diff\u00e8rent<\/em><\/li><li><em>O\u00f9 se situe l\u2019AMETEK Western Research 888L entre les architectures 900ADA et 888<\/em><\/li><li><em>Pourquoi le conditionnement d\u2019\u00e9chantillon et les conditions environnementales sont importants dans les applications de r\u00e9cup\u00e9ration du soufre<\/em><\/li><li><em>Comment les diagnostics et l\u2019acc\u00e8s \u00e0 l\u2019IHM soutiennent la maintenance et le d\u00e9pannage<\/em><\/li><li><em>Quels \u00e9l\u00e9ments examiner avant de choisir ou de remplacer un analyseur de gaz r\u00e9siduaires<\/em><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e3c6dfd elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"e3c6dfd\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b0d239c\" data-id=\"b0d239c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b9707bd red-dot elementor-widget elementor-widget-text-editor\" data-id=\"b9707bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Pourquoi l\u2019architecture de l\u2019analyseur est importante<\/strong><strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08e023c elementor-widget elementor-widget-text-editor\" data-id=\"08e023c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019analyse des gaz r\u00e9siduaires joue un r\u00f4le important dans l\u2019exploitation des unit\u00e9s de r\u00e9cup\u00e9ration du soufre. L\u2019analyseur fournit les mesures de H\u2082S et de SO\u2082 utilis\u00e9es pour aider les op\u00e9rateurs \u00e0 comprendre et \u00e0 contr\u00f4ler l\u2019\u00e9quilibre de combustion et la chimie r\u00e9actionnelle du proc\u00e9d\u00e9.<\/p><p>Lorsque les mesures de H\u2082S et de SO\u2082 sont stables et repr\u00e9sentatives, elles soutiennent de meilleures d\u00e9cisions d\u2019exploitation. Lorsque ces lectures deviennent retard\u00e9es, instables ou difficiles \u00e0 maintenir, le probl\u00e8me ne vient pas toujours de l\u2019analyseur lui-m\u00eame.<\/p><p>Dans bien des cas, le probl\u00e8me est li\u00e9 \u00e0 la fa\u00e7on dont l\u2019\u00e9chantillon est pr\u00e9lev\u00e9, conditionn\u00e9, transport\u00e9, chauff\u00e9 ou rendu accessible pour la maintenance.<\/p><p>Un analyseur de gaz r\u00e9siduaires fait partie d\u2019un syst\u00e8me de mesure complet. Ce syst\u00e8me comprend la prise d\u2019\u00e9chantillon sur le proc\u00e9d\u00e9, la sonde, le trajet de l\u2019\u00e9chantillon, le contr\u00f4le de la temp\u00e9rature, l\u2019emplacement de l\u2019analyseur, les diagnostics et l\u2019acc\u00e8s pour la maintenance. Si une partie de ce syst\u00e8me est mal adapt\u00e9e \u00e0 l\u2019application, la mesure peut en souffrir.<\/p><p>C\u2019est pourquoi le choix entre une architecture extractive, mont\u00e9e directement sur la conduite ou hybride n\u2019est pas seulement une pr\u00e9f\u00e9rence de conception. C\u2019est une d\u00e9cision de fiabilit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0bc9c16 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"0bc9c16\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-15c4360\" data-id=\"15c4360\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a6f6037 red-dot elementor-widget elementor-widget-text-editor\" data-id=\"a6f6037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Trois architectures d\u2019analyseurs de gaz r\u00e9siduaires <\/strong><strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee1ea6b elementor-widget elementor-widget-text-editor\" data-id=\"ee1ea6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><thead><tr><td style=\"text-align: center;\"><p><span style=\"color: #bf2f38;\"><strong>Architecture<\/strong><\/span><\/p><\/td><td style=\"text-align: center;\"><p><span style=\"color: #bf2f38;\"><strong>Fonctionnement<\/strong><\/span><\/p><\/td><td style=\"text-align: center;\"><p><span style=\"color: #bf2f38;\"><strong>Principal avantage<\/strong><\/span><\/p><\/td><td style=\"text-align: center;\"><p><span style=\"color: #bf2f38;\"><strong>Principal compromis<\/strong><\/span><\/p><\/td><\/tr><\/thead><tbody><tr><td><p>Analyseur extractif<\/p><\/td><td><p>L\u2019\u00e9chantillon est retir\u00e9 du proc\u00e9d\u00e9 et transport\u00e9 vers un analyseur situ\u00e9 dans un b\u00e2timent ou un abri \u00e0 distance.<\/p><\/td><td><p>L\u2019analyseur est prot\u00e9g\u00e9 et plus facile d\u2019acc\u00e8s.<\/p><\/td><td><p>Le syst\u00e8me de conditionnement d\u2019\u00e9chantillon devient critique.<\/p><\/td><\/tr><tr><td><p>Analyseur mont\u00e9 directement sur la conduite<\/p><\/td><td><p>L\u2019analyseur est install\u00e9 directement sur la conduite de proc\u00e9d\u00e9.<\/p><\/td><td><p>La mesure est plus proche du proc\u00e9d\u00e9, avec moins de transport d\u2019\u00e9chantillon.<\/p><\/td><td><p>L\u2019analyseur doit fonctionner dans l\u2019environnement de la zone proc\u00e9d\u00e9.<\/p><\/td><\/tr><tr><td><p>Architecture hybride 888L<\/p><\/td><td><p>L\u2019\u00e9chantillonnage directement sur la conduite est combin\u00e9 \u00e0 une interface d\u2019analyseur install\u00e9e \u00e0 distance.<\/p><\/td><td><p>Elle\u00a0permet d\u2019\u00e9quilibrer l\u2019\u00e9chantillonnage pr\u00e8s du proc\u00e9d\u00e9 avec l\u2019acc\u00e8s \u00e0 distance \u00e0 l\u2019interface et aux diagnostics.<\/p><\/td><td><p>Elle exige tout de m\u00eame une r\u00e9vision du routage de la ligne d\u2019\u00e9chantillon, de la temp\u00e9rature et de l\u2019acc\u00e8s pour la maintenance.<\/p><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9d2583f elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"9d2583f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a2dd6f1\" data-id=\"a2dd6f1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-704bed1 elementor-widget elementor-widget-text-editor\" data-id=\"704bed1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cette comparaison ne vise pas \u00e0 choisir une seule \u00ab meilleure \u00bb architecture pour toutes les applications. Elle vise plut\u00f4t \u00e0 comprendre ce que chaque architecture exige de l\u2019installation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b80bda6 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"b80bda6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-be3c5ae\" data-id=\"be3c5ae\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e74e71c red-dot elementor-widget elementor-widget-text-editor\" data-id=\"e74e71c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Analyse extractive des gaz r\u00e9siduaires<\/strong>\u00a0<strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd142f2 elementor-widget elementor-widget-text-editor\" data-id=\"cd142f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019architecture d\u2019analyse extractive retire l\u2019\u00e9chantillon du proc\u00e9d\u00e9 et le transporte vers un analyseur install\u00e9 \u00e0 l\u2019\u00e9cart de la conduite, souvent dans un b\u00e2timent d\u2019analyseurs ou un abri.<\/p><p>Cette approche peut \u00eatre pratique lorsque l\u2019analyseur doit \u00eatre prot\u00e9g\u00e9 de l\u2019environnement de la zone proc\u00e9d\u00e9, ou lorsque les \u00e9quipes de maintenance ont besoin d\u2019un acc\u00e8s plus facile \u00e0 l\u2019analyseur, aux utilit\u00e9s, \u00e0 l\u2019\u00e9quipement d\u2019\u00e9talonnage et \u00e0 l\u2019interface utilisateur. C\u2019est le type d\u2019installation que plusieurs utilisateurs associent au 900ADA.<\/p><p>Le compromis est que le syst\u00e8me de conditionnement d\u2019\u00e9chantillon devient une partie critique de la mesure.<\/p><p>Une fois que l\u2019\u00e9chantillon quitte le proc\u00e9d\u00e9, il doit demeurer repr\u00e9sentatif jusqu\u2019\u00e0 son arriv\u00e9e \u00e0 l\u2019analyseur. Les longues lignes chauff\u00e9es, les points froids aux raccords ou aux supports, les filtres obstru\u00e9s, les d\u00e9bits instables et l\u2019acc\u00e8s difficile \u00e0 la sonde peuvent tous influencer la capacit\u00e9 de l\u2019\u00e9chantillon \u00e0 repr\u00e9senter fid\u00e8lement le proc\u00e9d\u00e9 au moment de la mesure.<\/p><p>Autrement dit, l\u2019approche extractive place l\u2019analyseur dans un emplacement prot\u00e9g\u00e9, mais accorde plus d\u2019importance au syst\u00e8me d\u2019\u00e9chantillonnage. Ce n\u2019est pas une faiblesse lorsque le syst\u00e8me est bien con\u00e7u et bien entretenu. C\u2019est simplement la r\u00e9alit\u00e9 d\u2019ing\u00e9nierie de cette architecture.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a55e418 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"a55e418\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a04eaa9\" data-id=\"a04eaa9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-402aa70 red-dot elementor-widget elementor-widget-text-editor\" data-id=\"402aa70\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Analyse des gaz r\u00e9siduaires mont\u00e9e directement sur la conduite<\/strong> <strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3108e12 elementor-widget elementor-widget-text-editor\" data-id=\"3108e12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019architecture mont\u00e9e directement sur la conduite adopte une approche diff\u00e9rente.<\/p><p>Au lieu de transporter l\u2019\u00e9chantillon vers un analyseur \u00e0 distance, l\u2019analyseur est install\u00e9 directement sur la conduite de proc\u00e9d\u00e9. Cela r\u00e9duit le besoin d\u2019un syst\u00e8me traditionnel de conditionnement d\u2019\u00e9chantillon extractif et rapproche la mesure du proc\u00e9d\u00e9.<\/p><p>Un trajet d\u2019\u00e9chantillon plus court peut r\u00e9duire le nombre d\u2019endroits o\u00f9 l\u2019\u00e9chantillon peut refroidir, se boucher, condenser ou changer avant d\u2019\u00eatre mesur\u00e9. Il peut aussi r\u00e9duire le nombre de composants du syst\u00e8me d\u2019\u00e9chantillonnage qui n\u00e9cessitent une inspection et une maintenance r\u00e9guli\u00e8res.<\/p><p>Le compromis se situe au niveau de l\u2019environnement d\u2019installation.<\/p><p>L\u2019analyseur doit alors fonctionner l\u00e0 o\u00f9 se trouve la conduite, avec la m\u00eame exposition aux conditions ext\u00e9rieures, les m\u00eames limites d\u2019acc\u00e8s, les m\u00eames vibrations et les m\u00eames contraintes de maintenance que les autres \u00e9quipements de la zone proc\u00e9d\u00e9. L\u2019usine doit d\u00e9terminer si le point d\u2019\u00e9chantillonnage est pratique pour les v\u00e9rifications de routine, les travaux d\u2019\u00e9talonnage et l\u2019interaction avec l\u2019analyseur.<\/p><p>Un analyseur mont\u00e9 directement sur la conduite peut \u00eatre un excellent choix lorsque le point d\u2019\u00e9chantillonnage est accessible et que l\u2019environnement est ad\u00e9quat. Il peut \u00eatre moins pratique lorsque l\u2019emplacement du proc\u00e9d\u00e9 est expos\u00e9, difficile d\u2019acc\u00e8s ou peu adapt\u00e9 \u00e0 un acc\u00e8s r\u00e9gulier \u00e0 l\u2019interface de l\u2019analyseur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a177f5a elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"a177f5a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1638752\" data-id=\"1638752\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0c9b1d7 red-dot elementor-widget elementor-widget-text-editor\" data-id=\"0c9b1d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>O\u00f9 se situe l\u2019AMETEK 888L<\/strong><strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-fe8e3d1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"fe8e3d1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-76df982\" data-id=\"76df982\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-df3a906 elementor-widget elementor-widget-text-editor\" data-id=\"df3a906\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #0073a8;\"><a style=\"color: #0073a8;\" href=\"https:\/\/novatech.ca\/product\/ametek-888-sulphur-recovery-tail-gas-analyzer\/\" target=\"_blank\" rel=\"noopener\">L\u2019AMETEK Western Research 888L<\/a><\/span> a \u00e9t\u00e9 d\u00e9velopp\u00e9 pour les applications qui ne s\u2019inscrivent pas clairement dans l\u2019une ou l\u2019autre des deux cat\u00e9gories traditionnelles.<\/p><p>Il combine l\u2019\u00e9chantillonnage directement sur la conduite avec une interface d\u2019analyseur install\u00e9e \u00e0 distance. L\u2019\u00e9chantillon peut \u00eatre pr\u00e9lev\u00e9 \u00e0 la conduite, pr\u00e8s du proc\u00e9d\u00e9, tandis que l\u2019interface de l\u2019analyseur et les composants connexes peuvent \u00eatre install\u00e9s \u00e0 distance, par exemple dans un b\u00e2timent ou un abri.<\/p><p>C\u2019est cette combinaison qui rend l\u2019architecture du 888L utile. Elle fait le pont entre l\u2019installation extractive de type 900ADA et l\u2019architecture 888 mont\u00e9e directement sur la conduite.<\/p><p>Pour les utilisateurs finaux, cela signifie qu\u2019il n\u2019est pas n\u00e9cessaire de forcer chaque application dans l\u2019une des deux cat\u00e9gories traditionnelles. Un site peut vouloir b\u00e9n\u00e9ficier des avantages d\u2019un \u00e9chantillonnage pr\u00e8s du proc\u00e9d\u00e9, tout en conservant l\u2019interface de l\u2019analyseur dans un emplacement plus prot\u00e9g\u00e9 ou plus accessible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-1a85199\" data-id=\"1a85199\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f43e140 elementor-widget__width-auto elementor-widget elementor-widget-image\" data-id=\"f43e140\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"923\" src=\"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/888l-atex-and-iecex-zone-1-cell-electronics-and-customer-connection-enclosures-768x923.png\" class=\"attachment-medium_large size-medium_large wp-image-3454\" alt=\"AMETEK Western Research 888L hybrid tail gas analyzer for SRU H\u2082S and SO\u2082 measurement. - Novatech\" srcset=\"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/888l-atex-and-iecex-zone-1-cell-electronics-and-customer-connection-enclosures-768x923.png 768w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/888l-atex-and-iecex-zone-1-cell-electronics-and-customer-connection-enclosures-250x300.png 250w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/888l-atex-and-iecex-zone-1-cell-electronics-and-customer-connection-enclosures-852x1024.png 852w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/888l-atex-and-iecex-zone-1-cell-electronics-and-customer-connection-enclosures-1278x1536.png 1278w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/888l-atex-and-iecex-zone-1-cell-electronics-and-customer-connection-enclosures.png 1579w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-70e421c elementor-widget elementor-widget-text-editor\" data-id=\"70e421c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>C\u2019est particuli\u00e8rement pertinent pour les clients qui connaissent le 900ADA et qui \u00e9valuent leurs options de cycle de vie. La discussion ne devrait pas seulement \u00eatre : \u00ab Qu\u2019est-ce qui remplace l\u2019analyseur existant? \u00bb Elle devrait aussi \u00eatre : \u00ab Quelle architecture convient le mieux \u00e0 la prochaine \u00e9tape de cette installation? \u00bb<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-560af2f elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"560af2f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2828aa7\" data-id=\"2828aa7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4855b6b red-dot elementor-widget elementor-widget-text-editor\" data-id=\"4855b6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Environnement, diagnostics et acc\u00e8s pour la maintenance<\/strong> <strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2fe1f9 elementor-widget elementor-widget-text-editor\" data-id=\"e2fe1f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La temp\u00e9rature ambiante est un facteur important dans les installations d\u2019analyseurs de proc\u00e9d\u00e9.<\/p><p>Dans un syst\u00e8me extractif, l\u2019analyseur peut \u00eatre prot\u00e9g\u00e9 dans un abri, mais l\u2019\u00e9chantillon doit tout de m\u00eame voyager du proc\u00e9d\u00e9 jusqu\u2019\u00e0 l\u2019analyseur. Les lignes d\u2019\u00e9chantillon chauff\u00e9es, l\u2019isolation, le routage et le contr\u00f4le de la temp\u00e9rature deviennent donc critiques.<\/p><p>Dans un syst\u00e8me mont\u00e9 directement sur la conduite, le trajet de l\u2019\u00e9chantillon est r\u00e9duit, mais l\u2019analyseur est davantage expos\u00e9 \u00e0 l\u2019environnement autour de la conduite de proc\u00e9d\u00e9.<\/p><p>Le 888L offre une option hybride en permettant de pr\u00e9lever l\u2019\u00e9chantillon \u00e0 la conduite tout en gardant l\u2019interface de l\u2019analyseur dans un emplacement plus appropri\u00e9. Cela peut \u00eatre utile lorsque des contraintes environnementales rendent une installation enti\u00e8rement mont\u00e9e sur la conduite moins int\u00e9ressante, mais qu\u2019un syst\u00e8me extractif traditionnel introduit davantage de complexit\u00e9 dans le conditionnement d\u2019\u00e9chantillon.<\/p><p>Les diagnostics comptent aussi.<\/p><p>Lorsqu\u2019une lecture devient instable, les \u00e9quipes de maintenance doivent comprendre si le probl\u00e8me est li\u00e9 \u00e0 l\u2019analyseur, au trajet de l\u2019\u00e9chantillon, au proc\u00e9d\u00e9, au d\u00e9bit, \u00e0 la temp\u00e9rature ou \u00e0 une autre condition. Une information de diagnostic claire aide \u00e0 cerner le probl\u00e8me avant que les techniciens commencent \u00e0 retirer des pi\u00e8ces ou \u00e0 chercher la mauvaise cause.<\/p><p>Pour en savoir plus sur le r\u00f4le des pratiques de service dans la fiabilit\u00e9 des analyseurs \u00e0 long terme, consultez notre article sur <span style=\"color: #0073a8;\"><a style=\"color: #0073a8;\" href=\"https:\/\/ressources.novatech.ca\/fr\/blogue\/astuces-et-conseils\/maintenance-analyseurs-procede-service\/\" target=\"_blank\" rel=\"noopener\">la maintenance des analyseurs de proc\u00e9d\u00e9 et la discipline de service.<\/a><\/span><\/p><p>L\u2019architecture du 888L soutient cette approche en permettant d\u2019installer l\u2019interface de l\u2019analyseur \u00e0 distance du point d\u2019\u00e9chantillonnage sur le proc\u00e9d\u00e9. Pour plusieurs usines, cela signifie que les op\u00e9rateurs et les techniciens peuvent acc\u00e9der aux informations de l\u2019analyseur dans un emplacement plus pratique, plut\u00f4t que de d\u00e9pendre uniquement d\u2019une interaction directement \u00e0 la conduite.<\/p><p>Une inspection r\u00e9guli\u00e8re demeure toutefois n\u00e9cessaire. La prise d\u2019\u00e9chantillon, la sonde, les lignes chauff\u00e9es et l\u2019analyseur doivent toujours \u00eatre entretenus correctement. Mais l\u2019architecture hybride peut aider \u00e0 r\u00e9duire certains des compromis qui existaient traditionnellement entre les architectures extractives et les analyseurs mont\u00e9s directement sur la conduite.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8de6629 elementor-section-full_width elementor-hidden-tablet elementor-hidden-mobile elementor-section-height-default elementor-section-height-default\" data-id=\"8de6629\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6df97e1\" data-id=\"6df97e1\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;slideshow&quot;,&quot;background_slideshow_slide_transition&quot;:&quot;slide_down&quot;,&quot;background_slideshow_gallery&quot;:[],&quot;background_slideshow_slide_duration&quot;:5000,&quot;background_slideshow_transition_duration&quot;:500}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1677418 elementor-widget elementor-widget-text-editor\" data-id=\"1677418\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 style=\"text-align: left;\"><span style=\"color: #ffffff;\">Vous planifiez votre prochaine mise \u00e0 niveau d\u2019analyseur SRU?<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ede141c elementor-widget elementor-widget-text-editor\" data-id=\"ede141c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: left;\"><span style=\"font-size: 14pt;\">D\u00e9couvrez comment l\u2019architecture hybride du 888L soutient une mesure fiable des gaz de queue dans les applications SRU.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8330edf elementor-widget elementor-widget-button\" data-id=\"8330edf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/novatech.ca\/fr\/product\/ametek-888-analyseur-gaz-residuaires-soufre\/\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"far fa-arrow-alt-circle-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">EXPLORER LE 888L<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-81bba26 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"81bba26\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b53e831\" data-id=\"b53e831\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7d54fc7 red-dot elementor-widget elementor-widget-text-editor\" data-id=\"7d54fc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Ce qu\u2019il faut examiner avant de choisir<\/strong> <strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51856d1 elementor-widget elementor-widget-text-editor\" data-id=\"51856d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Avant de choisir entre une architecture extractive, mont\u00e9e directement sur la conduite ou hybride pour l\u2019analyse des gaz r\u00e9siduaires, il faut examiner toute la boucle de mesure :<\/p><ul><li>Le point d\u2019\u00e9chantillonnage du proc\u00e9d\u00e9 est-il repr\u00e9sentatif et accessible?<\/li><li>L\u2019\u00e9chantillon peut-il demeurer stable entre le proc\u00e9d\u00e9 et le point de mesure?<\/li><li>Les lignes chauff\u00e9es, l\u2019isolation et le routage sont-ils adapt\u00e9s \u00e0 l\u2019application?<\/li><li>Existe-t-il des points froids, de longues lignes ou des points d\u2019acc\u00e8s qui cr\u00e9ent r\u00e9guli\u00e8rement des probl\u00e8mes de maintenance?<\/li><li>L\u2019emplacement de l\u2019analyseur est-il pratique pour un acc\u00e8s s\u00e9curitaire, l\u2019\u00e9talonnage et l\u2019inspection?<\/li><li>Les diagnostics sont-ils disponibles l\u00e0 o\u00f9 les op\u00e9rateurs et les techniciens peuvent les utiliser efficacement?<\/li><li>L\u2019analyseur actuel est-il remplac\u00e9 en raison de son \u00e2ge, de la complexit\u00e9 du syst\u00e8me d\u2019\u00e9chantillonnage, de contraintes environnementales ou d\u2019une planification de cycle de vie?<\/li><\/ul><p>Ces questions permettent de relier davantage la d\u00e9cision d\u2019analyse \u00e0 la fa\u00e7on dont l\u2019unit\u00e9 fonctionne r\u00e9ellement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c606d7a elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"c606d7a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e299827\" data-id=\"e299827\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4b0458d red-dot elementor-widget elementor-widget-text-editor\" data-id=\"4b0458d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Conclusion <\/strong><strong><span style=\"color: #bf2f38;\">.<\/span><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33299b3 elementor-widget elementor-widget-text-editor\" data-id=\"33299b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019analyse des gaz r\u00e9siduaires dans les unit\u00e9s de r\u00e9cup\u00e9ration du soufre n\u2019est pas une application universelle.<\/p><p>Les syst\u00e8mes d\u2019analyse extractifs, les analyseurs mont\u00e9s directement sur la conduite et les architectures hybrides r\u00e9pondent chacun \u00e0 des besoins diff\u00e9rents. Le meilleur choix d\u00e9pend de l\u2019environnement de l\u2019usine, des conditions d\u2019\u00e9chantillonnage, des contraintes d\u2019installation et de la strat\u00e9gie de maintenance.<\/p><p>L\u2019AMETEK Western Research 888L offre aux utilisateurs finaux une troisi\u00e8me option. Il fait le pont entre l\u2019approche extractive traditionnelle de type 900ADA et l\u2019architecture 888 mont\u00e9e directement sur la conduite, en combinant l\u2019\u00e9chantillonnage direct du proc\u00e9d\u00e9 avec la flexibilit\u00e9 d\u2019une interface d\u2019analyseur install\u00e9e \u00e0 distance.<\/p><p>Pour les usines qui \u00e9valuent leurs options d\u2019analyse des gaz r\u00e9siduaires, en particulier celles qui connaissent le 900ADA, le 888L m\u00e9rite d\u2019\u00eatre \u00e9valu\u00e9 non seulement comme un analyseur plus r\u00e9cent, mais comme une architecture diff\u00e9rente qui pourrait mieux convenir aux exigences complexes et propres \u00e0 chaque site dans les applications de r\u00e9cup\u00e9ration du soufre.<\/p><p>L\u2019objectif est de choisir l\u2019architecture d\u2019analyseur qui offre \u00e0 l\u2019usine une mesure fiable, un acc\u00e8s pratique pour la maintenance et la meilleure ad\u00e9quation avec le fonctionnement r\u00e9el de l\u2019unit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7d66116 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"7d66116\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c741b6b\" data-id=\"c741b6b\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b57d761 elementor-widget elementor-widget-heading\" data-id=\"b57d761\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Soyez les premiers \u00e0 lire nos articles.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb3c763 elementor-widget elementor-widget-formidable\" data-id=\"fb3c763\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"formidable.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<link rel='stylesheet' id='formidable-css' href='https:\/\/ressources.novatech.ca\/wp-content\/plugins\/formidable\/css\/formidableforms.css?ver=626125' media='all' \/>\n<div class=\"frm_forms  with_frm_style frm_inline_form frm_style_formidable-style\" id=\"frm_form_11_container\" >\n<form enctype=\"multipart\/form-data\" method=\"post\" class=\"frm-show-form btn-right frm_pro_form \" id=\"form_contact-form22\" >\n<div class=\"frm_form_fields \">\n<fieldset>\n<legend class=\"frm_screen_reader\">Infolettre<\/legend>\r\n\r\n<div class=\"frm_fields_container\">\n<input type=\"hidden\" name=\"frm_action\" value=\"create\" \/>\n<input type=\"hidden\" name=\"form_id\" value=\"11\" \/>\n<input type=\"hidden\" name=\"frm_hide_fields_11\" id=\"frm_hide_fields_11\" value=\"\" \/>\n<input type=\"hidden\" name=\"form_key\" value=\"contact-form22\" \/>\n<input type=\"hidden\" name=\"item_meta[0]\" value=\"\" \/>\n<input type=\"hidden\" id=\"frm_submit_entry_11\" name=\"frm_submit_entry_11\" value=\"1d9ffb2760\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/fr\/wp-json\/wp\/v2\/blog\/3434\" \/><div id=\"frm_field_90_container\" class=\"frm_form_field  frm_html_container form-field\">\n<div class=\"newsletter-cta-button\"><a href=\"https:\/\/ressources.novatech.ca\/blog\/#form\">Subscribe to newsletter<\/a><\/div>\n<div class=\"newsletter-cta-button form-fr\"><a href=\"https:\/\/ressources.novatech.ca\/fr\/blogue\/#formulaire\">S'inscrire \u00e0 l'infolettre<\/a><\/div>\n<\/div>\n<div id=\"frm_field_56_container\" class=\"frm_form_field form-field  frm_required_field frm_none_container frm_two_thirds email-grid\">\r\n    <label for=\"field_29yf4d\" class=\"frm_primary_label\">Courriel\r\n        <span class=\"frm_required\"><\/span>\r\n    <\/label>\r\n    <input type=\"email\" id=\"field_29yf4d\" name=\"item_meta[56]\" value=\"\"  placeholder=\"Saisissez votre adresse \u00e9lectronique\" data-reqmsg=\"Ce champ ne peut pas \u00eatre vide\" aria-required=\"true\" data-invmsg=\"Veuillez saisir un courriel valide\" aria-invalid=\"false\"  \/>\r\n    \r\n    \r\n<\/div>\n\t<input type=\"hidden\" name=\"item_key\" value=\"\" \/>\n\t\t\t<div id=\"frm_field_91_container\">\n\t\t\t<label for=\"field_1ce9w\" >\n\t\t\t\tSi vous \u00eates un humain, ne remplissez pas ce champ.\t\t\t<\/label>\n\t\t\t<input  id=\"field_1ce9w\" type=\"text\" class=\"frm_form_field form-field frm_verify\" name=\"item_meta[91]\" value=\"\"  \/>\n\t\t<\/div>\n\t\t<input name=\"frm_state\" type=\"hidden\" value=\"jnAOxU1o+C9xKOBgM4ROMX6PbeiI0LuSJMgAYgFTg3FGSTRZbPZX5ztqX007KQze\" \/><div class=\"frm_submit frm_third arrow-form\">\r\n\r\n<button class=\"btn frm_button_submit frm_final_submit\" type=\"submit\"   formnovalidate=\"formnovalidate\">Inscrivez-vous<\/button>\r\n\r\n<\/div><\/div>\n<\/fieldset>\n<\/div>\n\n<\/form>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1239079 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"1239079\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1e8bcad\" data-id=\"1e8bcad\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ace1ef4 elementor-widget elementor-widget-image\" data-id=\"ace1ef4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-150x150.png\" class=\"attachment-thumbnail size-thumbnail wp-image-3140\" alt=\"Stuart Simmonds - Novatech\" srcset=\"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-150x150.png 150w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-300x300.png 300w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447-768x768.png 768w, https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2025\/10\/stuart-s-trial-fotor-20241028111447.png 1011w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42d12de elementor-widget elementor-widget-text-editor\" data-id=\"42d12de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R\u00e9dig\u00e9 par\u00a0 <strong><a href=\"https:\/\/www.linkedin.com\/in\/stuart-simmonds-1936b0117\/\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Stuart Simmonds<\/span><\/a><a href=\"https:\/\/www.linkedin.com\/in\/stuart-simmonds-1936b0117\/\" target=\"_blank\" rel=\"noopener\"> &#8211; <\/a><\/strong><span style=\"font-size: 10pt;\"><em><span class=\"_fadeIn_pfttw_8\">VP\u00a0<\/span><span class=\"_fadeIn_pfttw_8\">D\u00e9veloppement\u00a0<\/span><span class=\"_fadeIn_pfttw_8\">des\u00a0<\/span><span class=\"_fadeIn_pfttw_8\">affaires &amp;\u00a0<\/span><span class=\"_fadeIn_pfttw_8\">Marketing<\/span><\/em><\/span><\/p><p>\u00c9crivez \u00e0 Stuart \u00e0 l\u2019adresse suivante: <a href=\"mailto:stuart.simmonds@novatech.ca\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">stuart.simmonds@novatech.ca<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>R\u00e9dig\u00e9 par Stuart Simmonds &#8211; VP D\u00e9veloppement\u00a0des\u00a0affaires &amp;\u00a0Marketing 7 Juillet, 2026 AMETEK Western Research est \u00e0 l\u2019avant-garde de l\u2019analyse pour la r\u00e9cup\u00e9ration du soufre depuis plus de 50 ans. Au fil des ann\u00e9es, l\u2019entreprise a d\u00e9velopp\u00e9 diff\u00e9rentes architectures d\u2019analyseurs de gaz r\u00e9siduaires afin de r\u00e9pondre \u00e0 diverses exigences environnementales et applicatives dans les unit\u00e9s de [&hellip;]<\/p>\n","protected":false},"featured_media":3450,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"categorie-article":[55],"class_list":["post-3434","blog","type-blog","status-publish","has-post-thumbnail","hentry","categorie-article-applications"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.1 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride? | Blog Novatech<\/title>\n<meta name=\"description\" content=\"Comparez les architectures extractive, sur conduite et hybride pour l\u2019analyse des gaz r\u00e9siduaires SRU et la fiabilit\u00e9 des mesures H\u2082S et SO\u2082.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride?\" \/>\n<meta property=\"og:description\" content=\"Le choix d\u2019un analyseur de gaz r\u00e9siduaires n\u2019est pas toujours une simple d\u00e9cision de remplacement d\u2019un produit par un autre. Comparez les architectures extractive, mont\u00e9e directement sur la conduite et hybride pour les applications de r\u00e9cup\u00e9ration du soufre, et voyez o\u00f9 se situe l\u2019AMETEK 888L.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog Novatech\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-09T18:37:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/sru-blog-cover-page.png\" \/>\n\t<meta property=\"og:image:width\" content=\"630\" \/>\n\t<meta property=\"og:image:height\" content=\"230\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/\",\"url\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/\",\"name\":\"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride? | Blog Novatech\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ressources.novatech.ca\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/sru-blog-cover-page.png\",\"datePublished\":\"2026-07-09T13:46:35+00:00\",\"dateModified\":\"2026-07-09T18:37:31+00:00\",\"description\":\"Comparez les architectures extractive, sur conduite et hybride pour l\u2019analyse des gaz r\u00e9siduaires SRU et la fiabilit\u00e9 des mesures H\u2082S et SO\u2082.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ressources.novatech.ca\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/sru-blog-cover-page.png\",\"contentUrl\":\"https:\\\/\\\/ressources.novatech.ca\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/sru-blog-cover-page.png\",\"width\":630,\"height\":230,\"caption\":\"Sulphur recovery unit in a refinery process plant with piping, towers, and industrial equipment used in gas processing and analyzer applications\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Applications\",\"item\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/blogue\\\/applications\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/\",\"name\":\"Blog Novatech\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/#organization\",\"name\":\"Blog Novatech\",\"url\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ressources.novatech.ca\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/logo-novatech.svg\",\"contentUrl\":\"https:\\\/\\\/ressources.novatech.ca\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/logo-novatech.svg\",\"width\":302,\"height\":39,\"caption\":\"Blog Novatech\"},\"image\":{\"@id\":\"https:\\\/\\\/ressources.novatech.ca\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride? | Blog Novatech","description":"Comparez les architectures extractive, sur conduite et hybride pour l\u2019analyse des gaz r\u00e9siduaires SRU et la fiabilit\u00e9 des mesures H\u2082S et SO\u2082.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/","og_locale":"fr_FR","og_type":"article","og_title":"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride?","og_description":"Le choix d\u2019un analyseur de gaz r\u00e9siduaires n\u2019est pas toujours une simple d\u00e9cision de remplacement d\u2019un produit par un autre. Comparez les architectures extractive, mont\u00e9e directement sur la conduite et hybride pour les applications de r\u00e9cup\u00e9ration du soufre, et voyez o\u00f9 se situe l\u2019AMETEK 888L.","og_url":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/","og_site_name":"Blog Novatech","article_modified_time":"2026-07-09T18:37:31+00:00","og_image":[{"width":630,"height":230,"url":"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/sru-blog-cover-page.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/","url":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/","name":"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride? | Blog Novatech","isPartOf":{"@id":"https:\/\/ressources.novatech.ca\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/#primaryimage"},"image":{"@id":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/#primaryimage"},"thumbnailUrl":"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/sru-blog-cover-page.png","datePublished":"2026-07-09T13:46:35+00:00","dateModified":"2026-07-09T18:37:31+00:00","description":"Comparez les architectures extractive, sur conduite et hybride pour l\u2019analyse des gaz r\u00e9siduaires SRU et la fiabilit\u00e9 des mesures H\u2082S et SO\u2082.","breadcrumb":{"@id":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/#primaryimage","url":"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/sru-blog-cover-page.png","contentUrl":"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2026\/07\/sru-blog-cover-page.png","width":630,"height":230,"caption":"Sulphur recovery unit in a refinery process plant with piping, towers, and industrial equipment used in gas processing and analyzer applications"},{"@type":"BreadcrumbList","@id":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/analyse-gaz-residuaires-sru-extractive-sur-conduite-hybride\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/ressources.novatech.ca\/fr\/"},{"@type":"ListItem","position":2,"name":"Applications","item":"https:\/\/ressources.novatech.ca\/fr\/blogue\/applications\/"},{"@type":"ListItem","position":3,"name":"Analyse des gaz r\u00e9siduaires SRU : extractive, sur conduite ou hybride?"}]},{"@type":"WebSite","@id":"https:\/\/ressources.novatech.ca\/fr\/#website","url":"https:\/\/ressources.novatech.ca\/fr\/","name":"Blog Novatech","description":"","publisher":{"@id":"https:\/\/ressources.novatech.ca\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ressources.novatech.ca\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/ressources.novatech.ca\/fr\/#organization","name":"Blog Novatech","url":"https:\/\/ressources.novatech.ca\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/ressources.novatech.ca\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2023\/11\/logo-novatech.svg","contentUrl":"https:\/\/ressources.novatech.ca\/wp-content\/uploads\/2023\/11\/logo-novatech.svg","width":302,"height":39,"caption":"Blog Novatech"},"image":{"@id":"https:\/\/ressources.novatech.ca\/fr\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ressources.novatech.ca\/fr\/wp-json\/wp\/v2\/blog\/3434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ressources.novatech.ca\/fr\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/ressources.novatech.ca\/fr\/wp-json\/wp\/v2\/types\/blog"}],"version-history":[{"count":0,"href":"https:\/\/ressources.novatech.ca\/fr\/wp-json\/wp\/v2\/blog\/3434\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ressources.novatech.ca\/fr\/wp-json\/wp\/v2\/media\/3450"}],"wp:attachment":[{"href":"https:\/\/ressources.novatech.ca\/fr\/wp-json\/wp\/v2\/media?parent=3434"}],"wp:term":[{"taxonomy":"categorie-article","embeddable":true,"href":"https:\/\/ressources.novatech.ca\/fr\/wp-json\/wp\/v2\/categorie-article?post=3434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}